WATER PERFUSED MANOMETRY

This brochure describes our re-usable main non-sleeve catheters. These are tailored to meet the needs
of routine clinical laboratories.
Our more specialized sleeve catheters, which also have major clinical utility, are described in a companion brochure.

Benefits and Features

  • Reduced diameter of 4mm for oesophageal manometry in adults.
  • Smaller diameters suited to children.
  • Flexible silicone rubber enhances patient tolerance.
       
  • Autoclavable, a unique feature.
  • No risk of exposure to harmful chemicals.
  • Catheters kept in sealed pouches between use.
  • A dry, sterile catheter each time.
       
  • Our designs are backed by complete technical insight.
  • Special 'no deadspace' connectors eliminate bubble traps.
  • Durable silicone rubber does not degrade with use.
  • Enhanced patient tolerance - enhanced recordings.
  • Every catheter is performance and quality tested.
       
  • CE marked and FDA cleared.
  • Available in most countries.
       
  • Expert advice on best design solutions.
  • Flexible production processes.
  • Tailormade designs if needed.
       

    Adult Catheter Specification

    Spec E114
    Outer Diameter - 4mm
    Internal Diameter Pressure Lumen Channels - 0.67mm
    Internal Diameter Core Lumen Channel - 1.39mm
    Recommended flow/perfusion rate - 0.45ml/min-0.60ml/min

    Total length 170-180cm
    Working length 120-130cm


    Child Anorectal Catheters are the same specifications as Adult Catheters (E114)

    Spec E1 Outer Diameter - 4.7mm
    Internal Diameter Pressure Lumen Channels - 0.74mm
    Internal Diameter Core Lumen Channel - 1.55mm
    Recommended flow/perfusion rate - 0.45ml/min-0.60ml/min

    Total length 170-180cm
    Working length 120-130cm

    Child Catheter Specification 0 - 6 Years

    Spec E3
    Outer Diameter - 2.5mm
    Internal Diameter Pressure Lumen Channels - 0.6mm
    Recommended flow/perfusion rate - 0.45ml-0.60ml/min

    Total length 170-180cm
    Working length 120-130cm


    Child Catheter Specification 6 - 12 Years

    Spec E27
    Outer Diameter - 3.5mm
    Internal Diameter Pressure Lumen Channels - 0.65mm
    Internal Diameter Core Lumen Channel - 0.9mm
    Recommended flow/perfusion rate - 0.45ml-0.60ml/min

    Total length 170-180cm
    Working length 120-130cm

     